Description
Chiller Water Cooling System
Industrial Water Chiller for Factories
Precise Temperature Control Industrial Cooling System


Cooling System for Industrial Applications

- Located in a tropical zone with year-round high temperatures, industrial operations involving machinery and electronic equipment face challenges with overheating. Excessive heat can lead to equipment malfunction, reduced efficiency, and in severe cases, fire hazards. Similar to how elevated body temperature affects human health and performance, excessive heat in machinery impairs its functionality. Therefore, maintaining optimal operating temperatures through effective cooling solutions like chillers is crucial for machine maintenance and performance.

- A chiller is a refrigeration unit designed to produce cooling. Available in various sizes, its primary function is to lower and regulate temperature by transferring heat. It typically utilizes water as the medium for heat exchange, circulating cooled water to dissipate heat from the equipment. Chillers are widely employed in industrial settings to manage the thermal load of machinery, extending equipment lifespan and maintaining operational efficiency.

- Water serves as the primary medium for heat exchange and dissipation from the cooling unit.
- Chillers are integral to industrial operations for dissipating machine heat, ensuring longevity, and preserving equipment performance.
- Applications include closed-loop systems, hydraulic injection molding machines, and CNC machinery.
- Common applications: Closed system ponds, Hydraulic injection molding machines, CNC Engraving Cutting CO2, CNC Laser Engraving UV, CNC Router Milling, CNC Fiber Laser, and other industrial equipment.
Industrial Chiller for Sale – Model JL-3000
Designed for cooling CNC machines, fiber lasers, and other equipment, the JL-3000 ensures optimal operating temperatures, preventing overheating during intensive use.

FEATURES
- Refrigeration Capacity: 50W/°C
- Compact and energy-efficient thermolysis water cooler.
- Equipped with a comprehensive water flow alarm system.
- Ideal for CNC Laser, CNC Fiber Laser, and CNC CO2 Laser applications.
- Typical operating temperature range: 25-32°C.
LIMITATIONS
- This model does not feature a compressor and therefore does not provide active temperature control.
- The unit will adjust the water temperature to ambient conditions.
Machine Dimensions
Front View

Rear View, Inlet/Outlet Ports, Ventilation Fan, Drain Port

Machine Dimensions Overview

Machine Components Diagram

Technical Specifications

Operational Limitations of Chiller Models JL/CW-3000

Compressor
- JL/CW-3000: Not Equipped
- JL/CW-5000 and above: Equipped
Temperature Control
- JL/CW-3000: Passive temperature regulation (ambient dependent)
- JL/CW-5000 and above: Active temperature control
Temperature Regulation Behavior
- JL/CW-3000: The unit passively adjusts water temperature towards ambient conditions. For instance, if the ambient temperature is 32°C, the unit will work to lower the water temperature to approximately 32°C.
- JL/CW-5000 and above: Actively regulates temperature to a user-defined setpoint. Operation is contingent upon the water temperature reaching the set threshold.
User Manual Download for Chiller JL-3000: Click Here
Industrial Chiller Model Comparison (Water Chillers)
Chiller Water Cooling Model JL Series

Operational Principle: Laser Tube CO2 and Chiller System Integration



Optional Accessory: Heat Exchanger

The Heat Exchanger, when integrated with a chiller and submerged in water, further enhances cooling efficiency.
Available for an additional 3,000 THB.




Heat Exchanger Installation with Chiller System

Heat Exchanger: Additional Accessory for Chillers to Achieve Lower Water Temperatures | SALECNC.net
Chiller Water Cooling vs. Cooling Tower
Cooling Towers are commonly used in industries such as plastic injection molding. However, they present several disadvantages: large footprint, open-system operation making them susceptible to dust and debris ingress, which can lead to contamination, corrosion, and reduced lifespan. Consequently, industrial facilities are increasingly adopting Chiller Water Cooling systems due to their compact size, space efficiency, closed-system design that prevents contamination, and extended operational life.

| Cooling Tower | Chiller Water Cooling |
|---|---|
| ❌ Open System | ✅ Closed System |
| ❌ Susceptible to dust and debris ingress, leading to contamination, corrosion, and reduced equipment lifespan. | ✅ Prevents dust and debris ingress. Easy water change procedures. |
| ❌ Difficult maintenance and cleaning. | ✅ Simplified maintenance and cleaning. |
| ❌ Large footprint requiring significant workspace. | ✅ Compact design maximizes workspace efficiency. |
| ❌ Shorter operational lifespan. | ✅ Extended operational lifespan. |
| ❌ Lower initial cost but higher long-term expenses due to maintenance, repairs, and frequent replacement. | ✅ Higher initial investment but offers superior long-term cost-effectiveness through reduced maintenance and operational expenses. |
สนใจหรือติดต่อสอบถาม โทร LINE SCAN:
061-509-6388 (Chompoo)
098-997-4199 (Fern)
0615096199 (Banz)
0818071445 (Mint)
E-mail : [email protected]
Add Line: @123wotsb Fern (sales engineer) '
Add Line: @sales Chompoo (sales engineer)















salecnc.net
salecnc.net
salecnc.net