Description
Servo Transformer, Input 380V 3-Phase, Output 220V AC 3-Phase for Servo Motor/Drive

Calculation for Transformer Sizing based on Servo Motor Origin:
- China Servo Motor: Apply 1.2x AC Servo Transformer
- Taiwan Servo Motor: Apply 1.5x AC Servo Transformer
- Japan Servo Motor: Apply 2.0x AC Servo Transformer
- Europe/America Servo Motor: Apply 2.0x AC Servo Transformer
Example:
- Delta Servo (Taiwan) 2KW requires a 2KW x 1.5 = 3KW Transformer.
- Yaskawa (Japan), Panasonic 2KW requires a 2KW x 2.0 = 4KW Transformer.
***For Delta, Siemens, Schneider, connect as shown. Refer to diagrams for other brands.***

- Transformer 380V – 220V AC for Servo Motor/Drive
- Power Rating: 1.5 kW (Nominal, refer to specific model for exact rating)
- Low heat generation and minimal fan cooling required, optimizing other components’ lifespan.
- Compact design for reduced installation space.
- Lightweight construction compared to conventional transformers.
- Enhanced energy efficiency.